DESIGN
ENERGY
up to 2 600 mm Max sash height
up to 1 650 mm Max sash width
50 mm Max infill unit thickness
up to 150 kg Max sash weight
Uw >= 0.8 W/(m²K) Thermal insulation in accordance with EN ISO 10077-2
class E1200 (1200 Pa) Water tightness (EN 1027:2000, EN 12208:1999)
class 4 (600 Pa) Air permeability (EN 1026:2000, EN12207:1999)
class CE2400 (2400 Pa; 1/300) Wind load resistance (EN 12211:2000, EN 12210:1999)
up to 41dB Acoustic insulation (EN ISO 10140-2:2011, EN ISO 10140-4:2011)
3000 mm Maximum sash height
180 mm/280 mm Sash width
2500 mm Maximum sash height
1600 mm Maximum sash width
150 kg Maximum infill unit weight
68 mm Maximum infill unit thickness
Uf = 1.63 W/m2∙K Thermal insulation
Uw >= 0,7 W/m2∙K Thermal insulation
class E1200 (1 200 Pa) Water tightness
class 4 (600 Pa) Air permeability
class C5 (2 000 Pa) Wind load resistance
2500 mm Maximum sash height
1600 mm Maximum sash width
150 kg Maximum infill unit weight
68 mm Maximum infill unit thickness
Uf = 1.24 W/m2∙K Thermal insulation
Uw >= 0,7 W/m2∙K Thermal insulation
class E1200 (1 200 Pa) Water tightness
class 4 (600 Pa) Air permeability
class C5 (2 000 Pa) Wind load resistance
up to 47 dB Acoustic performance
26-107 mm Internal visible profile width
44-145 mm External visible profile width
26 mm Max infill unit thickness
140 kg Maximum infill unit weight
tilt and turn sashes Types of integrated constructions
glass bead profiles Method of infill unit fixation
up to 33 dB Acoustic insulation (depending on the infill unit used)
26-106 mm Internal visible profile width
48-150 mm External visible profile width
30 mm Max infill unit thickness
140 kg Maximum infill unit weight
turn only, T&T, sliding windows Types of integrated units
glass bead profiles Method of infill unit fixation
up to 33 dB Acoustic insulation (depending on the infill unit used)
up to 2 500 mm Max sash height
up to 1 600 mm Max sash width
50 mm Max infill unit thickness
up to 150 kg Max sash weight
1.3 W/m2*K Thermal insulation, Uw (EN ISO 12567-1:2011)
PAS 24:2016 (class W) Burglar resistance
class 4 (600 Pa) Air permeability (EN 1026:2000, EN12207:1999)
class E1500 (1500 Pa) Water tightness (EN 1027:2000, EN 12208:1999)
class B5 (2000 Pa; 1/200) Wind load resistance (EN 12211:2000, EN 12210:1999)
up to 36 dB Acoustic insulation (EN ISO 10140-2:2011, EN ISO 10140-4:2011)
up to 2 500 mm Max sash height
up to 1 600 mm Max sash width
50 mm Max infill unit thickness
up to 150 kg Max sash weight
1,3 W/m2*K Thermal insulation, Uw (EN ISO 12567-1:2011)
PAS 24:2016 (class W) Burglar resistance
class 4 (600 Pa) Air permeability (EN 1026:2000, EN12207:1999)
class E1500 (1500 Pa) Water tightness (EN 1027:2000, EN 12208:1999)
class B5 (2000 Pa; 1/200) Wind load resistance (EN 12211:2000, EN 12210:1999)
up to 36 dB Acoustic insulation (EN ISO 10140-2:2011, EN ISO 10140-4:2011)
up to 3 000 mm Max sash height
180 and 280 mm Sash width
Up to 2 450 mm Max sash height
Up to 1 600 mm Max sash width
40 mm Max infill unit thickness
Up to 150 kg Max sash weight
1,3 W/m2*K Thermal insulation, Uw (EN ISO 12567-1:2011)
PAS 24:2016 (class W) Burglar resistance
class 4 (600 Pa) Air permeability (EN 1026:2000, EN12207:1999)
class E1500 (1500 Pa) Water tightness (EN 1027:2000, EN 12208:1999)
class B5 (2000 Pa; 1/200) Wind load resistance (EN 12211:2000, EN 12210:1999)
up to 36 dB Acoustic insulation (EN ISO 10140-2:2011, EN ISO 10140-4:2011)
up to 2 500 mm Max sash height
up to 1 600 mm Max sash width
50 mm Max infill unit thickness
Up to 150 kg Max sash weight
1.3 W/m2*K Thermal insulation, Uw (EN ISO 12567-1:2011)
PAS 24:2016 (class W) Burglar resistance
class 4 (600 Pa) Air permeability (EN 1026:2000, EN12207:1999)
class E1500 (1500 Pa) Water tightness (EN 1027:2000, EN 12208:1999)
class B5 (2000 Pa; 1/200) Wind load resistance (EN 12211:2000, EN 12210:1999)
up to 36 dB Acoustic insulation (EN ISO 10140-2:2011, EN ISO 10140-4:2011)
up to 2 500 mm Max sash height
up to 1 600 mm Max sash width
58 mm Max infill unit thickness
up to 150 kg Max sash weight
0,84 W/m2*K Thermal insulation, Uw (EN ISO 12567-1:2011)
PAS 24:2016 (class W) Burglar resistance
class E1200 (1200 Pa) Water tightness (EN 1027:2000, EN 12208:1999)
class 4 (600 Pa) Air permeability (EN 1026:2000, EN12207:1999)
class CE2400 (2400 Pa; 1/300) Wind load resistance (EN 12211:2000, EN 12210:1999)
up to 41 dB Acoustic insulation (EN ISO 10140-2:2011, EN ISO 10140-4:2011)
up to 2 500 mm Max sash height
up to 1 600 mm Max sash width
58 mm Max infill unit thickness
up to 150 kg Max sash weight
0,84 W/m2*K Thermal insulation, Uw (EN ISO 12567-1:2011)
PAS 24:2016 (class W) Burglar resistance
class E1200 (1200 Pa) Water tightness (EN 1027:2000, EN 12208:1999)
class 4 (600 Pa) Air permeability (EN 1026:2000, EN12207:1999)
class CE2400 (2400 Pa; 1/300) Wind load resistance (EN 12211:2000, EN 12210:1999)
up to 41 dB Acoustic insulation (EN ISO 10140-2:2011, EN ISO 10140-4:2011)
up to 2 200 mm Max sash height
up to 1 700 mm Max sash width
48 mm Max infill unit thickness
up to 180 kg Max sash weight
Uw>=1.4 W/m²·K Thermal insulation, Uf (EN ISO 12567-1:2011)
PAS 24:2016 (class W) Burglar resistance
class 4 (600 Pa) Air permeability (EN 1026:2000, EN12207:1999)
side hung - class 8A (450 Pa), top hung - class E1500 (1500 Pa) Water tightness (EN 1027:2000, EN 12208:1999)
side hung - class C5 (2000 Pa; 1/300), top hung - class CE2400 (2400 Pa; 1/300) Wind load resistance (EN 12211:2000, EN 12210:1999)
up to 2 200 mm Max sash height
up to 1700 mm Max sash width
56 mm Max infill unit thickness
up to 180 kg Max sash weight
Uf>=1,9 W/m2*K Thermal insulation (EN ISO 12567-1:2011)
PAS 24:2016 (class W) Burglar resistance
class 4 (600 Pa) Air permeability (EN 1026:2000, EN12207:1999)
class E1500 (1500 Pa) Water tightness (EN 1027:2000, EN 12208:1999)
class CE2400 (2400 Pa;1/300) Wind load resistance (EN 12211:2000, EN 12210:1999)
up to 3 000 mm Max sash height
180 and 280 mm Vent width
up to 2 700 mm Max sash height
up to 1 600 mm Max sash width
50 mm Max infill unit thickness
up to 150 kg Max sash weight
>=1,05 W/m2*K Thermal insulation, Uw (EN ISO 12567-1:2011)
PAS 24:2016 (class W) Burglar resistance
class 4 (600 Pa) Air permeability (EN 1026:2000, EN12207:1999)
class E1200 (1200 Pa) Water tightness (EN 1027:2000, EN 12208:1999)
class C5 (2000 Pa; 1/300) Wind load resistance (EN 12211:2000, EN 12210:1999)
up to 41dB Acoustic insulation (EN ISO 10140-2:2011, EN ISO 10140-4:2011)
up to 2 500 mm Max sash height
up to 1 600 mm Max sash width
58 mm Max infill unit thickness
up to 150 kg Max sash weight
0,84 W/m2*K Thermal insulation, Uw (EN ISO 12567-1:2011)
PAS 24:2016 (class W) Burglar resistance
class E1200 (1200 Pa) Water tightness (EN 1027:2000, EN 12208:1999)
class 4 (600 Pa) Air permeability (EN 1026:2000, EN12207:1999)
class CE2400 (2400 Pa; 1/300) Wind load resistance (EN 12211:2000, EN 12210:1999)
up to 41 dB Acoustic insulation (EN ISO 10140-2:2011, EN ISO 10140-4:2011)