Facades

Find a solution

DESIGN
SAFETY
ENERGY
50, 60, 80 mm Internal visible profile width
20, 40, 50, 60 mm External visible profile width
68 mm Max infill unit thickness
700 kg Max weight of the infill unit
6 201 cm4 Max moment of inertia
pressure plate Method of infill unit fixation
all ALUTECH window and door systems, integrated facade windows and roof vents Integated elements
Uf >= 1,35 W/m2∙K Thermal insulation (EN ISO 10077-2:2017)
Class R7 (600 Pa) Water tightness (EN 13830:2003)
Class A4 (600 Pa) Air permeability (EN 13830:2003)
2,4 (2400 Pa) Wind loads resistance, kN/m2 (EN 13830:2003)
Class E5 (external impact), Class I5 (internal impact) Impact resistance
up to 48 dB Acoustic insulation (depending on the infill unit used)
50, 60, 80 mm Internal visible profile width
40, 50 mm External visible profile width
68 mm Max infill unit thickness
700, 1000 kg Max weight of the infill unit
6 201 cm4 Max moment of inertia
pressure plate Method of infill unit fixation
all ALUTECH window and door systems, integrated facade windows and roof vents Integated elements
Uf >= 0.6 W/m2∙K Thermal insulation (EN ISO 10077-2:2017)
Class R7 (600 Pa) Water tightness (EN 13830:2003)
Class A4 (600 Pa) Air permeability (EN 13830:2003)
2,4 (2400 Pa) Wind loads resistance, kN/m2 (EN 13830:2003)
Class E5 (external impact), Class I5 (internal impact) Impact resistance
up to 48 dB Acoustic insulation (depending on the infill unit used)
50 mm Internal visible profile width
20 mm External visible profile width
62 mm Max infill unit thickness
650 kg Max weight of the infill unit
6 201 cm4 Max moment of inertia
bonding Method of infill unit fixation
all ALUTECH window and door systems, integrated facade windows and roof vents Integated elements
Uf >= 1,35 W/m2∙K Thermal insulation (EN ISO 10077-2:2017)
Class R7 (600 Pa) Water tightness (EN 13830:2003)
Class A4 (600 Pa) Air permeability (EN 13830:2003)
2,4 (2400 Pa) Wind loads resistance, kN/m2 (EN 13830:2003)
Class E5 (external impact), Class I5 (internal impact) Impact resistance
up to 48 dB Acoustic insulation (depending on the infill unit used)
50, 60, 80 mm Internal visible profile width
50, 60 mm External visible profile width
74 mm Max infill unit thickness
1100 kg Max weight of the infill unit
6 201 cm4 Max moment of inertia
pressure plate, decorative cap Method of infill unit fixation
all ALUTECH window and door systems, integrated facade windows and roof vents Integrated elements
Uf >= 0.6 W/m2∙K Thermal insulation (EN ISO 10077-2:2017)
Class R7 (600 Pa) Water tightness (EN 13830:2003)
Class A4 (600 Pa) Air permeability (EN 13830:2003)
2,4 (2400 Pa) Wind loads resistance, kN/m2 (EN 13830:2003)
Class E5 (external impact), Class I5 (internal impact) Impact resistance
up to 48 dB Acoustic insulation (depending on the infill unit used)
up to level 9 Seismic stability
E15 Fire resistance level
EI60 Fire cutoff point