50, 60, 80 mm Internal visible profile width
50, 60 mm External visible profile width
4-62, 68 mm Glass thickness
700, 1100 kg Max weight of the infill unit
6 201 cm4 Max moment of inertia
pressure plate, decorative cap Method of infill unit fixation
all ALUTECH window and door systems, integrated facade windows and roof vents Possibility of integration
Uf = 1,8 W/m2∙K Thermal insulation (EN ISO 10077-2:2017)
Class R7 (600 Pa) Water tightness (EN 13830:2003)
Class A4 (600 Pa) Air permeability (EN 13830:2003)
2,4 (2400 Pa) Wind loads resistance, kN/m2 (EN 13830:2003)
Class E5 (external impact), Class I5 (internal impact) Impact resistance
up to 48 dB Acoustic insulation (depending on the infill unit used)
up to level 9 Seismic stability
E15 Fire resistance level
EI60 Fire cutoff point
50 mm Internal visible profile width
20, 28 mm External visible profile width
28-58 mm Glass thickness
700 kg Max weight of the infill unit
6 201 cm4 Max moment of inertia
bonding Method of infill unit fixation
all ALUTECH window and door systems, integrated facade windows and roof vents Possibility of integration
Uf = 1,8 W/m2∙K Thermal insulation (EN ISO 10077-2:2017)
Class R7 (600 Pa) Water tightness (EN 13830:2003)
Class A4 (600 Pa) Air permeability (EN 13830:2003)
2,4 (2400 Pa) Wind loads resistance, kN/m2 (EN 13830:2003)
Class E5 (external impact), Class I5 (internal impact) Impact resistance
up to 48 dB Acoustic insulation (depending on the infill unit used)
up to level 9 Seismic stability
E15 Fire resistance level
EI60 Fire cutoff point
50, 60, 80 mm Internal visible profile width
40, 50 mm External visible profile width
4-62, 68 mm Glass thickness
700, 1000 kg Max weight of the infill unit
6 201 cm4 Max moment of inertia
pressure plate Method of infill unit fixation
all ALUTECH window and door systems, integrated facade windows and roof vents Possibility of integration
Uf = 1,8 W/m2∙K Thermal insulation (EN ISO 10077-2:2017)
Class R7 (600 Pa) Water tightness (EN 13830:2003)
Class A4 (600 Pa) Air permeability (EN 13830:2003)
2,4 (2400 Pa) Wind loads resistance, kN/m2 (EN 13830:2003)
Class E5 (external impact), Class I5 (internal impact) Impact resistance
up to 48 dB Acoustic insulation (depending on the infill unit used)
up to level 9 Seismic stability
E15 Fire resistance level
EI60 Fire cutoff point
50, 60, 80 mm Internal visible profile width
20, 28, 40, 50, 60 mm External visible profile width
4-62, 68 mm Glass thickness
700 kg Max weight of the infill unit
6 201 cm4 Max moment of inertia
pressure plate Method of infill unit fixation
all ALUTECH window and door systems, integrated facade windows and roof vents Possibility of integration
Uf = 1,8 W/m2∙K Thermal insulation (EN ISO 10077-2:2017)
Class R7 (600 Pa) Water tightness (EN 13830:2003)
Class A4 (600 Pa) Air permeability (EN 13830:2003)
2,4 (2400 Pa) Wind loads resistance, kN/m2 (EN 13830:2003)
Class E5 (external impact), Class I5 (internal impact) Impact resistance
up to 48 dB Acoustic insulation (depending on the infill unit used)
up to level 9 Seismic stability
E15 Fire resistance level
EI60 Fire cutoff point
50 mm Internal visible profile width
50 mm External visible profile width
4-62 mm Infill unit thickness
400 kg Max infill unit weight
432 cm4 Max moment of inertia
Clamp profile, decorative cap, clamp bar Infill unit fixing method
all ALUTECH window and door systems Types of integrated units
Uf = 1,8 W/m2∙K Thermal insulation (EN ISO 10077-2:2017)
Class R7 (600 Pa) Water tightness (EN 13830:2003)
Class A4 (600 Pa) Air permeability (EN 13830:2003)
2,4 (2400 Pa) Wind loads resistance, kN/m2 (EN 13830:2003)
Class E5 (external impact), Class I5 (internal impact) Impact resistance
50 mm Internal visible profile width
50mm External visible profile width
10-50mm Infill unit thickness
700 kg Max. Infill unit weight
911 cm4 Max. moment of inertia
clamp profile, decorative cap Method of infill unit fixation
ALT W62, W72 window and door systems, integrated facade windows, smoke hatches Types of integrated units
class R7 (600 Pa) Water tightness (EN 13830:2003)
class A4 (600 Pa) Air permeability (EN 13830:2003)
2400 Pa Wind-load resistance EN 13830:2003
class E5/I5 (external/ internal) impact Impact resistance EN 13830:2003
Up to 48 dB Acoustic insulation (depending on the infill unit used)
Е15; E30 Fire-resistant rating for external systems
EIW15; EIW45 Fire-resistant rating for internal systems
29 mm Internal visible profile width
65 mm External visible profile width
4-50 mm Infill unit thickness
150 kg Max. weight of infill unit
239 cm4 Max. moment of inertia
Clamp profile; decorative cap, glass beads Method of infill unit fixation
ALT window and door system with thermal insulation Types of integrated units
Uf = 2,23 W/m2∙K Thermal insulation (EN ISO 10077-2:2017)
65 mm Internal visible profile width
65 mm External visible profile width
56 mm Max. infill unit thickness
3600 mm Max. module height
2700 mm Max. sash width
500 kg Max. infill unit weight
Uf ≥ 0,8 W/м2∙K Thermal insulation EN ISO 10077-2:2017
56 mm Max. infill unit thickness
3600 mm Max. module height
2700 mm Max. sash width
500 kg Max. infill unit weight
Uf ≥ 0,8 W/м2∙K Thermal insulation EN ISO 10077-2:2017
56 mm Max. infill unit thickness
3600 mm Max. module height
2700 mm Max. sash width
500 kg Max. infill unit weight
Uf ≥ 0,8 W/м2∙K Thermal insulation EN ISO 10077-2:2017